![]() You can download a raw copy of the database here. Always cite the International Consortium of Investigative Journalists when using this data. The International Medical Devices Database is licensed under the Open Database License and its contents under Creative Commons Attribution-ShareAlike license. This database is not intended to provide medical advice and patients should check with their doctors to determine if it contains relevant information and if such information has medical implications for them. The same device may have different names in different countries. We are not suggesting or implying that any companies or other entities included in the International Medical Devices Database engaged in unlawful conduct or otherwise acted improperly. Move Bucky unit Philips Medical Systems, August 2006 from the horizontal position into the vertical position or tilt from 0° to -20°. Stop movement: Press button again or Press Raise/lower (manual) button. Medical devices help to diagnose, prevent and treat many injuries and diseases. Bucky unit lowers and tilts into the horizontal position, e.g. Explore more than 120,000 Recalls, Safety Alerts and Field Safety Notices of medical devices and their connections with their manufacturers.ĭo you work in the medical industry? Or have experience with a medical device? Our reporting is not done yet. Switching on the automatic circuit brakers. Transport of the geometry stand through narrow doors (< 120cm). Transport of the table base to the site of installation. Quality tested spare part of PHILIPS C-ARM P/N: 452222093322 Software, XSCOPE Rel. *) Serial cable for X-Scope: Service PC Com1 9xfemale sub-DĭuoDiagnost System Control Cockpit CB100X92 9xfemale sub-D − Standard tools − Two-way drilling machine or powerful accumulator drilling machine − Ratched with set of nuts up to 19mm − Plumb bob 4m − Service PC, X-Scope/XRG-Scope compatible (486 or better with built in CD Rom drive used for corrective maintenance cockpit) − 0-modem cable, X-Scope compatible, recommended length = 10m *) − PC-Hardkey with permission for Xscope / XRGscope − Precision-type spirit level 1 m − Earth bounding tester − 10 m measuring tapeįor transport: − Forklift, fork length >= 140cm Geometry brakes, drives, userinterfaces, electronic systemĬlimatic conditions in the room (class C1 indoor temperature controlled) − Ambient temperature C Mains voltage DuoDiagnost II/TV and geometry (via overcurrent circuit breaker and ON/OFF relay generator): − 400 V, 3-phase ceiling height (without movement restrictions) 2800 mm column heightģ.1.2 Movements Tabletop lateral movement Bucky Diagnost FS Part number 9891 Manufacturer Philips Medical Systems Sales & Service Region No. ![]() The firm uses site numbers instead of serial numbers. of this book Technical data of the DuoDiagnost column: Model / Serial Site numbers: 504495, 105355, 104447. A DuoDiagnost system consists of the following subsystems and possible main options: − DuoDiagnost table and column ( −15° /90°) − OPTIMUS C Generator 50kW − II−TV 23 cm − Last image hold − Digital Camera XTV8 AC − 17” monitorģ.1.1 Dimensions Mechanical dimensions see Z −1.1 ff. It is a mixed Radiography and Fluoroscopy screening system with freely moving tube arm for free cassette exposures (including bed or wheel chair exposures) or examination requiring large SID. The DuoDiagnost is a multifunctional low cost R&F system, that offers radiographic functionality and RF functionality. The Philips DigitalDiagnost (and BuckyDiagnost) training course covers Philips latest DR (Digital Radiography) system as well as the Bucky-based BuckyDiagnost system. INTRODUCTION AND TECHNICAL DATA Blank page Push the shaft out of the housing with a plastic hammer (1).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |